Hi-Rem+
OVERFIBERS SRL · #SKRHP0
Automatically collected from overfibers.com
Are you the manufacturer?Send us your data
Hi-Rem+
Zirconia Glass Fiber Post
The innovative fiber post with AAS (Active Adhesion System), the biomimetic matrix-integrated bonding principle of Hi-Rem+, to increase the adhesion with OverCEM SA Self-Adhesive luting cement through a tested chemical interaction.
Hi-Rem+ are glass fiber posts with conical-cylindrical shape.
As Overfibers post surfaces are particularly rough the silanization treatments are an optional.
Hi-Rem+, the Overfibers' patented fiber post, has the great advantage to be easily removable when it is necessary.
The central longitudinal axis of Hi-Rem+ is made of violet soft polymer macro-fiber, placing in this position doesn't affect the resistance of the post, because the stresses are minimal (neutral axis).
Clinical Directions
Hi-Rem+ are specific for teeth with missing or massively destroyed crowns as they present the maximum emergency diameter at the level where they come out of the root, according to the most recent studies regarding the root canal shapes of the teeth treated endodontically.
Their special quality is having a large emergency coronal diameter compared to the relatively small apical diameter: this design stabilizes the prosthetic core much more effectively, making the restoration more resistant to the displacing forces of mastication.
Features
Advantages
- Active Adhesion System to SA/SE Cements
- Chemical interaction with SA/SE Cements
- Highly retentive surface
- Increases the post / cement adhesion without weakening it with deep grooves
- 80% glass fiber with zirconia
- high flexure strength 1650 MPa
- Balanced flexure E-modulus
- 60 GPa to better stabilize the restoration
- Highly Translucent
- provides esthetics and light transmission
- Radiopacity
- 3.0 mm or 300% Al equivalent
- Fatigue Strength
- 5 Millions Cycles Without Breaking
- Sterilization in autoclave
- 135°C at 2.1 bar for 5 min. without any variation of their resistance
- Easy to remove
- safely with absolute certainty and without tooth damages
Product Information
| Manufacturer | OVERFIBERS SRL |
|---|---|
| Shape | conico-cilindrica |
| Design | Conical-cylindrical shape |
| Material | Fibras de vidrio de Circonia 80% |
| Proprietà | Traslucido, Radiopaco |
| Radiopacity | 3.0 mm or 300% Al equivalent |
| Composition | 80% fibra di vetro con zirconia |
| Sterilization | Autoclave a 135°C, 2.1 bar per 5 min |
| Available sizes | Four sizes with color coding |
Documents
- Hi-Rem+ (Hi Rem 03 2021 Rev 04) Document
- Hi-Rem+ (Hi Rem Over Post ITA Brochure SD R02) Brochure
- Studio comparativo della rimozione di un perno in … un nuovo concetto di perno Document
- Hi-Rem+ (MSDS Hi-Rem esp) Safety data sheet
- Prosthetic drill Document
- Hi-Rem+ (Hi Rem Over Post EN Brochure SD R02) Brochure
Documents for the product line
- Prosthetic drill (Drills EN IFU Rev 10 0125 3) Instructions for use
- Hi-Rem+ (MSDS Hi-Rem Hi-Rem Post ita) Safety data sheet
- Prosthetic Drill (MSDS Drill ita) Safety data sheet
- Prosthetic drill (PD PYD ED HED CLD CND … ITALIANO 2) Document
- Legame adesivo del perno in fibra con i cementi … of Bologna, Bologna, Italy Document
- Valutazione di un Perno in Fibra con un Sistema … and Elio Berutti, MD, DDS Document
- Studio comparativo della rimozione di un perno in … Maria, Santa Maria, Brazil Document
- Perdita di tessuto durante la rimozione del perno … Maria, Santa Maria, Brazil Document
and 17 more