Hi-Rem Prosthetic Post
OVERFIBERS SRL
Collecté automatiquement depuis overfibers.com
Vous êtes le fabricant ?Transmettez vos données
Texte du fabricant en anglais
Hi-Rem Prosthetic Post
Zirconia Glass Fiber Post
Hi-Rem Prosthetic Post are glass fiber posts with conical-cylindrical shape. As Overfibers post surfaces are particularly rough the silanization treatments are an optional.
Hi-Rem Post, the Overfibers' patented fiber post, has the great advantage to be easily removable when it is necessary.
The central longitudinal axis of Hi-Rem Prosthetic Post is made of soft polymer macro-fiber, placing in this position doesn't affect the resistance of the post, because the stresses are minimal (neutral axis).
Clinical Directions
Hi-Rem Prosthetic Post are specific for teeth with missing or massively destroyed crowns as they present the maximum emergency diameter at the level where they come out of the root, according to the most recent studies regarding the root canal shapes of the teeth treated endodontically. Their special quality is having a large emergency coronal diameter compared to the relatively small apical diameter: this design stabilizes the prosthetic core much more effectively, making the restoration more resistant to the displacing forces of mastication.
Features
Advantages
- Highly retentive surface: Increases the post / cement adhesion without weakening it with deep grooves
- 80% glass fiber with zirconia
- high flexure strength 1600 Mpa
- Balanced flexure E-modulus: 60 GPa to better stabilize the restoration
- Highly Translucent: provides esthetics and light transmission
- Radiopacity: 3.0 mm or 300% Al equivalent
- Fatigue Strength: 5 Millions Cycles Without Breaking
- Sterilization in autoclave: 135°C at 2.1 bar for 5 min without any variation of their resistance
- Easy to remove: safely with absolute certainty and without tooth damages
Hi-Rem Prosthetic Post and Prosthetic Drill are available in four sizes, with color coding for a corresponding use.
Specifications
| Maximum diameter | Point diameter | Root part conicity (%) | Total length | Drill | |
|---|---|---|---|---|---|
| RPOP100 | 1.20 | 0.70 | 0.04 | 19 | PD100 |
| RPOP101 | 1.40 | 0.80 | 0.05 | 19 | PD101 |
| RPOP102 | 1.60 | 0.80 | 0.066 | 19 | PD102 |
| RPOP103 | 1.80 | 0.90 | 0.08 | 19 | PD103 |
Informations produit
| Fabricant | OVERFIBERS SRL |
|---|---|
| Forme | cilíndrica-cónica |
| Forme | conical-cylindrical |
| Longueur | 19 mm |
| Surface | particularly rough |
| Module d'élasticité | 60 GPa |
| Radio-opacité | 3.0 mm or 300% Al equivalent |
| Composition | 80% fibra di vetro con zirconia |
| Stérilisation | 135°C at 2.1 bar for 5 min |
| Tailles disponibles | 4 sizes with color coding |
| Composition du matériau | 80% glass fiber with zirconia |
Documents
- Hi-Rem Prosthetic Post Document
Documents de la gamme
- Hi-Rem Prosthetic Post (MSDS Hi-Rem Hi-Rem Post eng) Fiche de données de sécurité
- Prosthetic Drill (MSDS Drill eng) Fiche de données de sécurité
- Hi-Rem Post (Hi Rem Prosthetic Post Brochure English) Brochure
- Evaluation of a Simplified Fiber Post Removal … and Elio Berutti, MD, DDS Document
- Fiber Post Removal: Comparative Study Using a New … Maria, Santa Maria, Brazil Document
- Tissue Loss During Post Removal: a New Post … Maria, Santa Maria, Brazil Document
- Prosthetic Drill (Drills EN IFU Rev 10 0125 3) Mode d'emploi
- Effect of Sterilization on Fiber Posts Fracture … of Bologna, Bologna, Italy Document
et 22 autres